Frequently asked questions about construction plans
Do I need to submit construction plans with my permits? Typically, most small residential projects do not require construction plans. However, on larger or more complex projects, or on commercial, institutional, educational, or industrial projects, plans and detailed specifications will be required. Anytime a design professional (Architect or Engineer) is involved in the project, plans will be required. Below are some common projects:
PROJECT | PLANS REQUIRED |
Minor Work | No |
Repairs | No |
Renovation | No |
New Addition | Yes |
Alteration | Yes |
Reconstruction | Yes |
Finished Basement | Yes |
New Deck | Yes |
Deck Repairs | No |
Pool (In-ground) | No |
Pool (Above-ground) | Yes |
Generator | Yes |
Is an Architect required to draft construction plans and specifications? Given the complexity of codes in New Jersey, it is highly recommended that a design professional (Architect or Engineer) be consulted for more complex projects that may require plans and specifications. The application for a Construction Permit shall be accompanied by two (2) copies of specifications and of plans drawn to scale, with sufficient clarity and detail dimensions to show the nature and character of the work to be performed and must demonstrate compliance with the requirements of the code and these regulations or to facilitate inspections for code conformity. Any plans prepared by a design professional must include a raised seal and signature on each page.
Can I draft my own plans as a Homeowner? Yes. The Construction Official shall waive the requirement for sealed plans in the case of a single family Homeowner who had prepared his or her own plans for the construction, addition, reconstruction, alteration, renovation, or repair of a detached structure used or intended to be used exclusively as his or her private residence providing that the owner shall submit an affidavit attesting to the fact that he or she has personally prepared the plans and provided further that said plans are in the opinion of the construction official, and appropriate subcode official, legible and complete for purposes of ensuring compliance with the regulations.
Can my contractor draft their own plans? Only Licensed Electrical, Plumbing, and Mechanical Contractors are permitted to draft construction plans for their specific discipline, providing the work is for a Class 3 Building, which includes 1 & 2 Family Homes. Home Improvement Contractors are NOT permitted to draft plans for homeowners.
What is required to be included in construction plans for a Single Family home? Any application for a construction permit for a single family residence shall be accompanied by at least two copies of plans drawn to scale, with sufficient clarity and detailed dimensions to show the nature and character of the work to be performed. Plans submitted shall not be required to show more detail or include more information than is reasonably necessary to assure compliance with the requirements of the Uniform Construction Code and rules in this chapter.
In order to meet minimum requirements, the plans must include the following details:
- Site diagram consisting of a site plan showing size and location of all new and existing construction on the site with distances from lot lines and indicating new building services, location and size.
- Construction plans consisting of a scale drawing showing foundation, floor plans, and elevations, including structural framing notes for all floors, ceilings and roofs. Only girders and columns need be identified and located on the plan. Included on the drawings shall be a loading schedule indicating the live loads for which the structure is designed.
- The following details and submissions shall be required:
- A cross section through one typical wall showing construction details from footing to and including roof framing. This section shall indicate all construction materials used including roofing, vapor barriers, sheathing type and thickness, insulation type and thickness, windows, glazing type if other than standard window glazing is used, interior finish material, floor type and thickness, structure, foundation and footings. Decorative material shall not be required to be shown unless it contributes to the structural integrity of the section.
- When roof or other truss systems are used, the details required by N.J.A.C. 5:23-2.15(f)1ii(1)(A) shall be shown.
- Electrical details indicating lighting; receptacles; motors and equipment; smoke detectors; service entrance locations; size and type (overhead or underground); panel size, location; number of proposed circuits. A symbol legend shall be included.
- Plumbing details indicating the locations of fixtures and a notice or table listing water and drainage pipe sizes. A note stating if sewage disposal is to public sewer or individual septic system shall be included.
- Mechanical details indicating the type of heating system; location, size and type of heating unit, noting the distribution method and indicating design rates, location of fire dampers and safeguards; and location, type and size of flue.
- Energy subcode compliance, applicable to new residences and additions to existing residences, shall be demonstrated with either detailed calculations, the submission of NJ Clean Energy Program for Residential New Construction compliance documentation or other "above code" program documentation, the submission of printouts from software recognized by the Department, such as REScheck, or conforming with the prescriptive packages described in the current energy subcode compliance bulletin. REScheck software is available from the U.S. Department of Energy at www.energycodes.gov.
NOTE: To document compliance using REScheck, users shall meet or exceed the applicable requirements of the Energy Subcode. Please see the current energy subcode compliance bulletin for further guidance.
Contact Us
-
Holmdel Township
4 Crawfords Corner Road
Holmdel, NJ 07733
Phone: 732-946-2820
Fax: 732-975-9774Office Hours
Monday through Friday
7:00 AM to 4:00 PM
~~~~~~~~~~~~~~~~~~~
Steven J. Winters, CFM
Director of Community Development,Construction Official
Ext. 1313 Email~~~~~~~~~~~~~~~~~~~
Staff Directory
Dawn Horniacek
Senior Technical Assistant
Ext. 1304 Email
~~~~~~~~~~~~~~~~~~~~
Nettie Thompson
Technical Assistant
Ext. 1306 Email
~~~~~~~~~~~~~~~~~~~~
Dina Rosado
Technical Assistant
Ext. 1307 Email
~~~~~~~~~~~~~~~~~~~~
Micheal Purazzo
Electric Subcode Official
Ext. 1312 Email
~~~~~~~~~~~~~~~~~~~~
Michael Winch
Plumbing Subcode Official
Ext. 1314 Email
~~~~~~~~~~~~~~~~~~~~
Dennis Sassa
Building Subcode Official
Ext. 1310 Email
~~~~~~~~~~~~~~~~~~~~
David Olsen
Fire Subcode Official
Ext. 1315 Email
~~~~~~~~~~~~~~~~~~~~